Output power
10 kVA / 9 kW
15 kVA / 13.5 kW
20 kVA / 18 kW
30 kVA / 27 kW
40 kVA / 36 kW
60 kVA / 54 kW
80 kVA / 72 kW
100 kVA / 90 kW
120 kVA / 108 kW
160kVA / 144kW
200 kVA / 180 kW

Number of phases
3/1 (10-100 kVA)
3/3 (10-200 kVA)

Configuration
tower

Master MPS series UPS provide maximum protection and power quality for mission critical loads, including data centres, industrial processes, telecommunications, security and electro-medical systems. Master MPS is an on-line double conversion UPS (VFI SS 111 – IEC EN 62040-3) with a transformer isolated inverter.

The Master MPS range includes three-phase input and single-phase output versions from 10 to 100 kVA, and three-phase input and output versions from 10 to 800 kVA. All versions are provided with a 6-pulse thyristor-based rectifier, with or without optional harmonic filters.
A 12-pulse thyristor-based rectifier is available on request for the 60 and 80 kVA versions (provided as standard for MPT 800), with or without optional harmonic filters.

Easy source

Master MPS makes supplying the UPS from generator sets and MT/BT transformers simpler and more efficient, reducing power loss in the system and coils, correcting the power factor and eliminating current harmonics created by the loads supplied by the UPS. In addition to this, the progressive rectifier start-up (power walk-in) and the option to reduce battery charging currents, allow for a reduction in the input current uptake. This means less demand on the source, which is particularly useful when the source is a generator set.

Power continuity

For years, Riello UPS has been developing and supplying solutions for the various requirements and problems that inevitably arise in critical applications. Riello UPS offers flexible, highly available solutions that are able to adapt to different system structures and criticality levels. Riello UPS builds UPS systems that can withstand multiple component or subsystem failures while continuing to operate normally, providing uninterrupted power. This is achieved through careful design, installation of redundant elements, elimination of common points of failure, planning of maintenance activities, control and supervision of system and environmental operating parameters. The TEC service team is ready to provide help and advice regarding projects.

Flexibility

Master MPS is suitable for a wide range of applications including IT and the most demanding industrial environments. The UPS is suitable for power capacitive loads such as blade servers, without any reduction in active power, from 0.9 leading to 0.8 lagging. With a broad range of accessories and options, complex configurations and system architectures can be achieved to guarantee maximum power availability and the option to add new UPS without interruption to existing installation.

Battery care system: maximum battery care

Normally the batteries are kept charged by the rectifier; when mains power fails, the UPS uses this energy source to power the consumers. Proper battery care is therefore critical to ensuring correct UPS operation under emergency conditions. The Riello UPS battery care system consists of a series of functions designed to optimise battery management and achieve the best performance and operating life possible. Master MPS is also compatible with different battery technologies:

  • Two-level charging mode to optimize charging currents and reduce charging time.
  • Temperature compensation and deep discharge protection to reduce aging and improve battery life.
  • Charge blocking system to reduce electrolyte consumption and extend the life of VRLA batteries.
  • Battery tests for early diagnosis of performance degradation or battery problems.

UPS Master MPS sources are compatible with various energy storage technologies – open lead-acid, VRLA AGM, Gel, NiCd and lithium batteries as well as supercapacitors and flywheels

Simple to install

Master MPS requires very little space for installation (only 0.64m2 for a 200 kVA system), in addition, the optimized design allows servicing of all main components from the front panel, without the need for access from the side. The Master MPS requires minimal space for access by using top-vented cabinets and front panel access.

Specific solutions

The UPS can be adapted to meet the most specific requirements. Contact our TEC team to discuss specific solutions and options not listed in this catalogue.

Maximum reliability and availability

  • Distributed or centralised paralel configuration of up to 8 units per redundant (N+1) or power parallel system. Parallel configurations using models with different power ratings are also possible.
  • Hot System Expansion (HSE): allows the addition of a further UPS into an existing system, without the need to switch off the existing UPS or transfer them to bypass mode. This guarantees maximum load protection, even during maintenance and system expansion.
  • Maximum levels of availability, even in the event of an interruption to the parallel bus cable: the system is “FAULT TOLERANT ”. It is not affected by connection cable faults and continues powering the load without disruption, signalling an alarm condition.
  • Efficiency Control System (ECS): a system to optimise the operating efficiency of parallel systems, according to the power required by the load. N+1 redundancy is guaranteed, with every UPS working in parallel at the best load level possible to achieve higher overall efficiency.

GENERAL FEATURES

  • Distributed or centralised paralel configuration of up to 8 units per redundant (N+1) or power parallel system. Parallel configurations using models with different power ratings are also possible.
  • Advanced cross-platform communication for all operating systems and network environments: PowerShield3 monitoring and shutdown software with SNMP agent for Windows 8, 7, 2008, Vista, 2003, XP, Linux, Mac OS X, Sun Solaris, Linux, Novell and other operating systems Unix systems
  • Maximum levels of availability, even in the event of an interruption to the parallel bus cable: the system is “FAULT TOLERANT ”. It is not affected by connection cable faults and continues powering the load without disruption, signalling an alarm condition.
  • RS232 serial and USB ports
  • Efficiency Control System (ECS): a system to optimise the operating efficiency of parallel systems, according to the power required by the load. N+1 redundancy is guaranteed, with every UPS working in parallel at the best load level possible to achieve higher overall efficiency.
  • Input for the connection of the auxiliary contact of an external manual bypass

Options

UPS Group Synchroniser (UGS)
Allows two or more non-parallel UPS devices to remain synchronised even during mains power failure. The UGS also enables a Riello UPS to be synchronised with another power source that is independent and of a different power rating.

Parallel Systems Joiner (PSJ)
Allows two groups of UPS to be connected in parallel whilst operating, in the event of maintenance (with no interruption to the output), using a power coupling switch. S hould one of the UPS in one of the parallel groups fail, it is automatically excluded. The PSJ connects the remaining UPS , to the other parallel group via an external bypass, in order to continue to guarantee load redundancy.