HIGHLIGHTS

  • Ultimate Availability
  • Ultimate scalability
  • Unmatched power density
  • Efficiency up to 98%
  • Multiple controls
  • Highly flexible
  • Advanced communications

Multi Power2 – M2X is our next-generation of modular UPS. It’s engineered for unmatched reliability, compactness and sustainability, delivering the best performance available on the market today.

It’s the best power solution for Small Data Centres & Critical Applications; designed to safeguard IT environments, the M2X ensures maximum availability while adapting seamlessly to your growing business needs. Say goodbye to oversized UPS systems—our solution scales effortlessly, optimizing both your initial investment and Total Cost of Ownership (TCO).

As your power demands increase, M2X expands its power capabilities maintaining top-tier power protection, availability, and redundancy, maximizing, at the same time, cost savings.

Multi Power2 – M2X empowers the Digital Age with Scalable, Secure & Efficient Energy. From healthcare and telecommunications to commerce, and education, digital technology drives every aspect of modern life. To keep these essential services running smoothly, data storage, processing and transfer systems require an ultra-reliable power source and that’s exactly what Multi Power delivers.

OUTSTANDING EFFICIENCY

Sustainability is one of today’s major challenges, no matter if we are dealing with huge data centres or small telecom applications.

That’s why we developed a brand new 2U power module able to reduce cooling needs and, at the same time, it creates more compact, reliable, and durable solutions even for small and medium power requirements.

Our modules achieve up to 98% efficiency in ON LINE double conversion, ensuring top-quality power supply for critical equipment while minimizing energy losses and operating costs.

Thanks to EFFICIENCY CONTROL Mode, our system automatically adjusts the number of active Power Modules based on demand. This optimizes efficiency, ensures redundancy, and maintains high performance, even at low loads. Additionally, M2X operates efficiently in temperatures up to 40°C without loss of performance, reducing the need for extra cooling.

With advanced technology, our system enables faster, and more reliable communication between components and delivers exceptional dynamic performance.

SCALABILITY

The Multi Power2 – M2X has been conceived to be fully customizable to meet the specific needs of each installation and quickly adapt to the load increase. Thanks to the hot-swappable features, the increase of power can be done while the unit is working in ON LINE double conversion without any disruption to the load. All the major components of the UPS are modular and can be easily added or replaced by the engineer, minimizing the site intervention costs.

M2X is available in three main configurations:

  • PCS – Power cabinet up to 120 kW
  • CBC – Combo cabinet up to 120 kW
  • CBC – Combo cabinet up to 90 kW

The Power cabinet can accommodate either 15 kW or 30 kW Power Modules. The available UPS power and redundancy level can be expanded vertically from:

  • 15 to 75 kW in one single Power cabinet (M2X 120 PCS with PM 15 BLUE or PM 15)
  • 30 to 120 kW plus redundancy in one single Power cabinet (M2X 120 PCS with PM 30 BLUE).

M2X Combo, instead, is built combining Power Modules and Battery Units in a unique cabinet.

This solution can be utilized within extremely compact areas requiring a small footprint with maximum power density. This modular and reliable solution is perfect for any small to medium business applications.

The Combo Cabinet M2X 120 CBC 6 has five slots for PMs and 6 battery shelves (up to 6 battery strings) and it can expand vertically from 15 to 75 kW (with PM 15 BLUE or PM 15) or 30 to 120 kW plus redundancy (with PM 30 BLUE).

The Combo Cabinet M2X 90 CBC 4 has three slots for PMs and 4 battery shelves (up to 4 battery strings) and it can expand vertically from 15 to 45 kW (with PM 15 BLUE or PM 15) or 30 to 90 kW (with PM 30 BLUE).

The combo units are engineered to accept cables coming from the top or the bottom, providing peace of mind to end users and installers.

The PMs are designed to be independent, hot-swappable, mechanically segregated and with embedded selective disconnection at both the input and output stage.

The Bypass is fully rated according to the maximum power of the UPS, enabling it to clear higher short circuit currents.

The units have been designed with several standard features:

  • Fans monitoring,
  • Backfeed detection circuit and protection,
  • Power walk-in,
  • Separate or common batteries (parallel systems).

A full set of options is available to fit the requirements of each installation, in both IT and non-IT environment:

  • Parallel configuration kit,
  • Cold start kit,
  • Top Ventilation for M2X 120 CBC,
  • Seismic ki.

THE MOST ADVANCED TECHNOLOGY

M2X, as per all Multi Power2 family, is the result of a new design focused on a deep interconnection between hardware and software.

  • Intelligence is distributed to ensure the protection of the equipment even on the off chance of a failure.
  • Internal communication structure is based on two separate and fully redundant high-speed buses.
  • Automatic health-checks are performed during the plug-in of each module to verify its status and avoid defective components.
  • Operation is completely risk-free and enables the user to increase the power or redundancy of the system while the UPS is protecting the load. If a module has a different firmware version, the system aligns it to one of the other modules.
  • Continuous monitoring via several sensors embedded in each module: to check the status of the UPS and analyse the running and environmental parameters to ensure the best operating performances.
  • Embedded interleaving technology grants a significant reduction of the ripple current values and extends the lifespan of the batteries and DC capacitors.

MULTIPLE CONTROLS

To provide the highest level of quality and process control, each component of the system, from the modules to the cabinet, is designed and manufactured in Italy; moreover, all suppliers are carefully selected through a strict process of approval. At the end of our production line, all modules and full units undergo specific tests to grant rated performances and product integrity.

All collected measurements and data are analysed to keep improving our products and provide our customers with the most updated technologies. To enhance the lifespan of the UPS, each module incorporates status counters, as well as temperature and humidity sensors, providing real-time analytics for operators.

FLEXIBLE MODULARITY

The Multi Power2 – M2X is equipped with a 10” colour touch screen display that simultaneously provides information, measurements and operating states of the entire system and of each individual power module.

The user interface also includes an LED bar which delivers immediate and clear information regarding the current status of the UPS. To ensure a simple, quick and full connection to the existing infrastructure, by default all Multi Power2 – M2X units are equipped with:

  • network card NetMan 208,
  • embedded configurable In/Out signals (5 inputs and 4 outputs),
  • 2 free slots for the installation of optional communication accessories such as network adaptors and extra volt free contacts,
  • R.E.P.O. Remote Emergency Power Off.

The units are also compatible with:

  • PowerShield3 monitoring and shutdown software included for Windows operating systems 11, 10, 8, Server 2022, 2019, 2016 and previous versions, Windows Server Virtualization Hyper-V, macOS, Linux, Citrix XenServer and other Unix operating systems.

ULTRA SERVICEABILITY

The unit was carefully engineered to simplify positioning, installation and maintenance operations.

Connection terminals are easily accessible for a safe and simple installation of the UPS. Thanks to the embedded intelligence, powerful computing capacity and outstanding connectivity, we can monitor remotely the status of the UPS and provide dynamic and dedicated services to increase its lifespan.