{"id":8555,"date":"2024-03-14T09:37:39","date_gmt":"2024-03-14T08:37:39","guid":{"rendered":"https:\/\/a2b.sk\/uncategorized\/delphys-mp-elite\/"},"modified":"2024-07-12T07:44:26","modified_gmt":"2024-07-12T05:44:26","slug":"delphys-mp-elite","status":"publish","type":"post","link":"https:\/\/a2b.sk\/en\/ups-systems\/on-line-vfi-above-to-10-kva\/delphys-mp-elite\/","title":{"rendered":"DELPHYS MP Elite+"},"content":{"rendered":"\n<p><strong>High quality power supply<\/strong><\/p>\n\n<ul class=\"wp-block-list\">\n<li>Permanent operation in VFI mode (online double conversion).<\/li>\n\n\n\n<li>Output voltage precision under all load conditions.<\/li>\n\n\n\n<li>High overload capability to withstand abnormal load conditions.<\/li>\n\n\n\n<li>A very high short-circuit current capacity which facilitates the selection of protective devices for selectivity in the downstream distribution.<\/li>\n\n\n\n<li>An isolation transformer installed on the inverter output to ensure complete galvanic isolation between DC circuit and load output. This insulation also provides a separation between the two inputs when they are supplied by different sources. <\/li>\n\n\n\n<li>Sinusoidal ThdU output voltage &lt; 2 % with linear loads and &lt; 4 % with non-linear loads.<\/li>\n<\/ul>\n\n<p><strong>High availability<\/strong><\/p>\n\n<ul class=\"wp-block-list\">\n<li>Field-proven technology.<\/li>\n\n\n\n<li>Fault-tolerant architecture with redundancy of basic functions, such as the ventilation system.<\/li>\n\n\n\n<li>Easy maintainability reduces MTTR thanks to pull-out sub-assemblies and front access all components.<\/li>\n\n\n\n<li>Accurate diagnostics guarantee power supply to the load.<\/li>\n\n\n\n<li>Cascade failure prevention for parallel systems.<\/li>\n\n\n\n<li>Mechanical &amp; electrical robustness for industrial environments.<\/li>\n\n\n\n<li>Soft start capability (ramp up) of the IGBT inverter allows a good operation even with a genset.<\/li>\n\n\n\n<li>Specifically designed to be adapted to different industrial environment: high IP protection options, high peak current capability, long back up time\u2026<\/li>\n<\/ul>\n\n<p><strong>Cost-effective equipment<\/strong><\/p>\n\n<p>The &#8220;clean&#8221; IGBT rectifier allows:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>a high efficiency,<\/li>\n\n\n\n<li>a high and constant input power factor,<\/li>\n\n\n\n<li>a low THDi.<\/li>\n<\/ul>\n\n<p>These characteristics help to limit the dimensions of upstream network infrastructure.<\/p>\n\n<ul class=\"wp-block-list\">\n<li>Possibility to create new neutral system without additional losses (extra transformer required on by-pass line only).<\/li>\n\n\n\n<li>High short-circuit capability simplifies downstream protective devices.<\/li>\n\n\n\n<li>High power density: its small footprint saves space on your premises.<\/li>\n\n\n\n<li>Mains connection of the rectifier requires only 3 cables (no neutral).<\/li>\n\n\n\n<li>Battery connection to UPS requires only 2 cables.<\/li>\n<\/ul>\n\n<p><strong>User-friendly operation<\/strong><\/p>\n\n<ul class=\"wp-block-list\">\n<li>A control panel with graphic display for more ergonomic operation.<\/li>\n\n\n\n<li>An array of &#8220;com-slot&#8221; plug-in communication interfaces, for upgrading your operating requirements evolution.<\/li>\n<\/ul>\n\n<p><strong>Simplified maintenance<\/strong><\/p>\n\n<ul class=\"wp-block-list\">\n<li>An advanced diagnostic system.<\/li>\n\n\n\n<li>A remote access device connected to the remote maintenance centre.<\/li>\n\n\n\n<li>Easy access to subassemblies and components, facilitating tests and reducing maintenance time (MTTR).<\/li>\n<\/ul>\n\n<p><br\/><strong>STANDARD AND OPTION FEATURES<\/strong><\/p>\n\n<p><strong>Standard communication features<\/strong><\/p>\n\n<ul class=\"wp-block-list\">\n<li>Dry-contact interface (configurable voltage-free contacts).<\/li>\n\n\n\n<li>3 slots for communication options.<\/li>\n<\/ul>\n\n<p><strong>Parallel systems<\/strong><\/p>\n\n<ul class=\"wp-block-list\">\n<li>Distributed or centralized bypass for parallel architecture up to 6 units.<\/li>\n\n\n\n<li>Redundant systems (&#8220;1+1&#8221; and &#8220;n+1&#8221;).<\/li>\n\n\n\n<li>&#8220;2n&#8221; architecture with Static Transfer Systems.<\/li>\n<\/ul>\n\n<p><strong>Standard electrical features<\/strong><\/p>\n\n<ul class=\"wp-block-list\">\n<li>Backfeed protection: detection circuit.<\/li>\n\n\n\n<li>Standard interface:\n<ul class=\"wp-block-list\">\n<li>3 inputs (emergency stop, generating set, battery protection),<\/li>\n\n\n\n<li>4 outputs (general alarm, back-up, bypass, preventative maintenance needs).<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n<p><strong>Electrical options<\/strong><\/p>\n\n<ul class=\"wp-block-list\">\n<li>EBS (Expert Battery System) (conditions apply).<\/li>\n\n\n\n<li>ACS synchronisation system for 2n architecture.<\/li>\n\n\n\n<li>Redundant electronic power supplies.<\/li>\n\n\n\n<li>Hot plug option (increase the power keeping the load supplied in double conversion).<\/li>\n\n\n\n<li>Rectifier with long backup time.<\/li>\n<\/ul>\n\n<p><strong>Optional mechanical equipment<\/strong><\/p>\n\n<ul class=\"wp-block-list\">\n<li>Increased degree of protection up to IP52.<\/li>\n\n\n\n<li>Dust filters.<\/li>\n\n\n\n<li>Fan redundancy with failure detection.<\/li>\n\n\n\n<li>User-friendly multilingual color graphic display with touch screen.<\/li>\n<\/ul>\n\n<p><strong>Communication options<\/strong><\/p>\n\n<ul class=\"wp-block-list\">\n<li>User-friendly multilingual color graphic display with touch screen.<\/li>\n\n\n\n<li>MODBUS RTU RS485 or TCP.<\/li>\n\n\n\n<li>PROFIBUS \/ PROFINET gateway.<\/li>\n\n\n\n<li>BACnet\/IP interface.<\/li>\n\n\n\n<li>NET VISION: professional WEB\/SNMP Ethernet interface for secure UPS monitoring and remote automatic shutdown.<\/li>\n\n\n\n<li>REMOTE VIEW PRO supervision software.<\/li>\n\n\n\n<li>IoT Gateway for Socomec cloud services and SOLIVE UPS mobile application.<\/li>\n\n\n\n<li>Additional Com-slot.<\/li>\n<\/ul>\n\n<p><strong>Remote monitoring and cloud services<\/strong><\/p>\n\n<ul class=\"wp-block-list\">\n<li>LINK-UPS: Remote monitoring service that allows to monitor your UPS by specialist 24 hours a day.<\/li>\n\n\n\n<li>SOLIVE UPS: mobile app enabling the monitoring of the UPS systems from a smartphone.<\/li>\n<\/ul>\n\n<p><strong>Application:<\/strong><\/p>\n\n<ul class=\"wp-block-list\">\n<li>Industry<\/li>\n\n\n\n<li>Processes<\/li>\n\n\n\n<li>Infrastructure<\/li>\n\n\n\n<li>Healthcare sector<\/li>\n\n\n\n<li>Service sector<\/li>\n\n\n\n<li>Telecommunication<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>High quality power supply High availability Cost-effective equipment The &#8220;clean&#8221; IGBT rectifier allows: These characteristics help to limit the dimensions of upstream network infrastructure. User-friendly operation Simplified maintenance STANDARD AND OPTION FEATURES Standard communication features Parallel systems Standard electrical features Electrical options Optional mechanical equipment Communication options Remote monitoring and cloud services Application:<\/p>\n","protected":false},"author":1,"featured_media":7792,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[136,132],"tags":[],"class_list":["post-8555","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-on-line-vfi-above-to-10-kva","category-ups-systems"],"acf":{"photo_gallery":{"galeria":[[{"id":7792,"title":"Delphys_mp_elite-web_img","caption":"","full_image_url":"https:\/\/a2b.sk\/wp-content\/uploads\/2024\/03\/Delphys_mp_elite-web_img.png","thumbnail_image_url":"https:\/\/a2b.sk\/wp-content\/uploads\/2024\/03\/Delphys_mp_elite-web_img-150x150.png","large_srcset":"https:\/\/a2b.sk\/wp-content\/uploads\/2024\/03\/Delphys_mp_elite-web_img.png 450w, https:\/\/a2b.sk\/wp-content\/uploads\/2024\/03\/Delphys_mp_elite-web_img-300x300.png 300w, https:\/\/a2b.sk\/wp-content\/uploads\/2024\/03\/Delphys_mp_elite-web_img-150x150.png 150w, https:\/\/a2b.sk\/wp-content\/uploads\/2024\/03\/Delphys_mp_elite-web_img-12x12.png 12w","medium_srcset":"https:\/\/a2b.sk\/wp-content\/uploads\/2024\/03\/Delphys_mp_elite-web_img-300x300.png 300w, https:\/\/a2b.sk\/wp-content\/uploads\/2024\/03\/Delphys_mp_elite-web_img-150x150.png 150w, https:\/\/a2b.sk\/wp-content\/uploads\/2024\/03\/Delphys_mp_elite-web_img-12x12.png 12w, https:\/\/a2b.sk\/wp-content\/uploads\/2024\/03\/Delphys_mp_elite-web_img.png 450w","media_details":{"width":450,"height":450,"sizes":{"medium":{"file":"Delphys_mp_elite-web_img-300x300.png","width":300,"height":300,"mime-type":"image\/png","filesize":65160,"source_url":"https:\/\/a2b.sk\/wp-content\/uploads\/2024\/03\/Delphys_mp_elite-web_img-300x300.png"},"thumbnail":{"file":"Delphys_mp_elite-web_img-150x150.png","width":150,"height":150,"mime-type":"image\/png","filesize":20877,"source_url":"https:\/\/a2b.sk\/wp-content\/uploads\/2024\/03\/Delphys_mp_elite-web_img-150x150.png"},"trp-custom-language-flag":{"file":"Delphys_mp_elite-web_img-12x12.png","width":12,"height":12,"mime-type":"image\/png","filesize":405,"source_url":"https:\/\/a2b.sk\/wp-content\/uploads\/2024\/03\/Delphys_mp_elite-web_img-12x12.png"}}},"alt_text":"","url":"","target":""}]]}},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v23.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>DELPHYS MP Elite+ - a2b - energy for the future<\/title>\n<meta name=\"description\" content=\"alternating current sources UPS On-line \/ VFI over 10 kVA DELPHYS MP Elite+ by A2B\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/a2b.sk\/en\/ups-systems\/on-line-vfi-above-to-10-kva\/delphys-mp-elite\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"DELPHYS MP Elite+ - a2b - energy for the future\" \/>\n<meta property=\"og:description\" content=\"alternating current sources UPS On-line \/ VFI over 10 kVA DELPHYS MP Elite+ by A2B\" \/>\n<meta property=\"og:url\" content=\"https:\/\/a2b.sk\/en\/ups-systems\/on-line-vfi-above-to-10-kva\/delphys-mp-elite\/\" \/>\n<meta property=\"og:site_name\" content=\"a2b - energy for the future\" \/>\n<meta property=\"article:published_time\" content=\"2024-03-14T08:37:39+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-07-12T05:44:26+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/a2b.sk\/wp-content\/uploads\/2024\/03\/Delphys_mp_elite-web_img.png\" \/>\n\t<meta property=\"og:image:width\" content=\"450\" \/>\n\t<meta property=\"og:image:height\" content=\"450\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"martin.skorvanek@gmail.com\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"martin.skorvanek@gmail.com\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/a2b.sk\/en\/ups-systems\/on-line-vfi-above-to-10-kva\/delphys-mp-elite\/\",\"url\":\"https:\/\/a2b.sk\/en\/ups-systems\/on-line-vfi-above-to-10-kva\/delphys-mp-elite\/\",\"name\":\"DELPHYS MP Elite+ - a2b - energy for the future\",\"isPartOf\":{\"@id\":\"https:\/\/a2b.sk\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/a2b.sk\/en\/ups-systems\/on-line-vfi-above-to-10-kva\/delphys-mp-elite\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/a2b.sk\/en\/ups-systems\/on-line-vfi-above-to-10-kva\/delphys-mp-elite\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/a2b.sk\/wp-content\/uploads\/2024\/03\/Delphys_mp_elite-web_img.png\",\"datePublished\":\"2024-03-14T08:37:39+00:00\",\"dateModified\":\"2024-07-12T05:44:26+00:00\",\"author\":{\"@id\":\"https:\/\/a2b.sk\/en\/#\/schema\/person\/3ecf1d51c0b501778e80355607e57503\"},\"description\":\"alternating current sources UPS On-line \/ VFI over 10 kVA DELPHYS MP Elite+ by A2B\",\"breadcrumb\":{\"@id\":\"https:\/\/a2b.sk\/en\/ups-systems\/on-line-vfi-above-to-10-kva\/delphys-mp-elite\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/a2b.sk\/en\/ups-systems\/on-line-vfi-above-to-10-kva\/delphys-mp-elite\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/a2b.sk\/en\/ups-systems\/on-line-vfi-above-to-10-kva\/delphys-mp-elite\/#primaryimage\",\"url\":\"https:\/\/a2b.sk\/wp-content\/uploads\/2024\/03\/Delphys_mp_elite-web_img.png\",\"contentUrl\":\"https:\/\/a2b.sk\/wp-content\/uploads\/2024\/03\/Delphys_mp_elite-web_img.png\",\"width\":450,\"height\":450},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/a2b.sk\/en\/ups-systems\/on-line-vfi-above-to-10-kva\/delphys-mp-elite\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"UPS systems\",\"item\":\"https:\/\/a2b.sk\/en\/ups-systems\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"On-line \/ VFI above to 10 kVA\",\"item\":\"https:\/\/a2b.sk\/en\/ups-systems\/on-line-vfi-above-to-10-kva\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"DELPHYS MP Elite+\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/a2b.sk\/en\/#website\",\"url\":\"https:\/\/a2b.sk\/en\/\",\"name\":\"a2b - energy for the future\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/a2b.sk\/en\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/a2b.sk\/en\/#\/schema\/person\/3ecf1d51c0b501778e80355607e57503\",\"name\":\"martin.skorvanek@gmail.com\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/a2b.sk\/en\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/208dbc3e4fe00b08d9d6c0bb38a0e94d?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/208dbc3e4fe00b08d9d6c0bb38a0e94d?s=96&d=mm&r=g\",\"caption\":\"martin.skorvanek@gmail.com\"},\"sameAs\":[\"https:\/\/a2b.sk\"],\"url\":\"https:\/\/a2b.sk\/en\/author\/martin-skorvanekgmail-com\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"DELPHYS MP Elite+ - a2b - energy for the future","description":"alternating current sources UPS On-line \/ VFI over 10 kVA DELPHYS MP Elite+ by A2B","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/a2b.sk\/en\/ups-systems\/on-line-vfi-above-to-10-kva\/delphys-mp-elite\/","og_locale":"en_US","og_type":"article","og_title":"DELPHYS MP Elite+ - a2b - energy for the future","og_description":"alternating current sources UPS On-line \/ VFI over 10 kVA DELPHYS MP Elite+ by A2B","og_url":"https:\/\/a2b.sk\/en\/ups-systems\/on-line-vfi-above-to-10-kva\/delphys-mp-elite\/","og_site_name":"a2b - energy for the future","article_published_time":"2024-03-14T08:37:39+00:00","article_modified_time":"2024-07-12T05:44:26+00:00","og_image":[{"width":450,"height":450,"url":"https:\/\/a2b.sk\/wp-content\/uploads\/2024\/03\/Delphys_mp_elite-web_img.png","type":"image\/png"}],"author":"martin.skorvanek@gmail.com","twitter_card":"summary_large_image","twitter_misc":{"Written by":"martin.skorvanek@gmail.com","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/a2b.sk\/en\/ups-systems\/on-line-vfi-above-to-10-kva\/delphys-mp-elite\/","url":"https:\/\/a2b.sk\/en\/ups-systems\/on-line-vfi-above-to-10-kva\/delphys-mp-elite\/","name":"DELPHYS MP Elite+ - a2b - energy for the future","isPartOf":{"@id":"https:\/\/a2b.sk\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/a2b.sk\/en\/ups-systems\/on-line-vfi-above-to-10-kva\/delphys-mp-elite\/#primaryimage"},"image":{"@id":"https:\/\/a2b.sk\/en\/ups-systems\/on-line-vfi-above-to-10-kva\/delphys-mp-elite\/#primaryimage"},"thumbnailUrl":"https:\/\/a2b.sk\/wp-content\/uploads\/2024\/03\/Delphys_mp_elite-web_img.png","datePublished":"2024-03-14T08:37:39+00:00","dateModified":"2024-07-12T05:44:26+00:00","author":{"@id":"https:\/\/a2b.sk\/en\/#\/schema\/person\/3ecf1d51c0b501778e80355607e57503"},"description":"alternating current sources UPS On-line \/ VFI over 10 kVA DELPHYS MP Elite+ by A2B","breadcrumb":{"@id":"https:\/\/a2b.sk\/en\/ups-systems\/on-line-vfi-above-to-10-kva\/delphys-mp-elite\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/a2b.sk\/en\/ups-systems\/on-line-vfi-above-to-10-kva\/delphys-mp-elite\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/a2b.sk\/en\/ups-systems\/on-line-vfi-above-to-10-kva\/delphys-mp-elite\/#primaryimage","url":"https:\/\/a2b.sk\/wp-content\/uploads\/2024\/03\/Delphys_mp_elite-web_img.png","contentUrl":"https:\/\/a2b.sk\/wp-content\/uploads\/2024\/03\/Delphys_mp_elite-web_img.png","width":450,"height":450},{"@type":"BreadcrumbList","@id":"https:\/\/a2b.sk\/en\/ups-systems\/on-line-vfi-above-to-10-kva\/delphys-mp-elite\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"UPS systems","item":"https:\/\/a2b.sk\/en\/ups-systems\/"},{"@type":"ListItem","position":2,"name":"On-line \/ VFI above to 10 kVA","item":"https:\/\/a2b.sk\/en\/ups-systems\/on-line-vfi-above-to-10-kva\/"},{"@type":"ListItem","position":3,"name":"DELPHYS MP Elite+"}]},{"@type":"WebSite","@id":"https:\/\/a2b.sk\/en\/#website","url":"https:\/\/a2b.sk\/en\/","name":"a2b - energy for the future","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/a2b.sk\/en\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/a2b.sk\/en\/#\/schema\/person\/3ecf1d51c0b501778e80355607e57503","name":"martin.skorvanek@gmail.com","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/a2b.sk\/en\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/208dbc3e4fe00b08d9d6c0bb38a0e94d?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/208dbc3e4fe00b08d9d6c0bb38a0e94d?s=96&d=mm&r=g","caption":"martin.skorvanek@gmail.com"},"sameAs":["https:\/\/a2b.sk"],"url":"https:\/\/a2b.sk\/en\/author\/martin-skorvanekgmail-com\/"}]}},"_links":{"self":[{"href":"https:\/\/a2b.sk\/en\/wp-json\/wp\/v2\/posts\/8555"}],"collection":[{"href":"https:\/\/a2b.sk\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/a2b.sk\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/a2b.sk\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/a2b.sk\/en\/wp-json\/wp\/v2\/comments?post=8555"}],"version-history":[{"count":1,"href":"https:\/\/a2b.sk\/en\/wp-json\/wp\/v2\/posts\/8555\/revisions"}],"predecessor-version":[{"id":9628,"href":"https:\/\/a2b.sk\/en\/wp-json\/wp\/v2\/posts\/8555\/revisions\/9628"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/a2b.sk\/en\/wp-json\/wp\/v2\/media\/7792"}],"wp:attachment":[{"href":"https:\/\/a2b.sk\/en\/wp-json\/wp\/v2\/media?parent=8555"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/a2b.sk\/en\/wp-json\/wp\/v2\/categories?post=8555"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/a2b.sk\/en\/wp-json\/wp\/v2\/tags?post=8555"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}